Forum Forum MESA !! Strona Główna
 Strona glówna  •  FAQ  •  Szukaj  •  Użytkownicy  •  Grupy  •  Galerie  •  Rejestracja  •   Profil  •  Zaloguj się, by sprawdzić wiadomości  •  Zaloguj 
EHV transmission line fault transient noise charac 
Napisz nowy temat   Odpowiedz do tematu    Forum Forum MESA !! Strona Główna -> Wyniki
Zobacz poprzedni temat :: Zobacz następny temat  
Autor
Wiadomość
e707004304
ORANGE EKSTRAKLASA



Dołączył: 17 Gru 2010
Posty: 612
Przeczytał: 0 tematów

Ostrzeżeń: 0/5
Skąd: England

PostWysłany: Śro 10:54, 06 Kwi 2011  

EHV transmission line fault transient noise characteristics of


Of the calculation, the phase fault , the parameters often used to solve the fault phase current and voltage pairs. According to this feature of distance protection , the following fault phase power to the noise characteristics of the analysis and discussion . In principle, the fault phase noise power statistical characteristics of the various phases through the transient fault to determine the statistical calculations . But this will involve more fault types , calculation is very complicated . Theoretical analysis and simulation results show that , if the system of positive sequence and negative sequence impedance is equal , no matter what type of phase fault , fault phase current and voltage components of the steady state and transient components are identical. Therefore, the noise power from the protection of the relevant characteristics of the actual can be attributed to single-phase fault and only two basic types of three-phase fault . Fault phase current and voltage of the noise statistical properties , see the preceding three-phase fault on the analysis of noise characteristics , the specific content here omitted. 3 Conclusion In this paper, digital simulation method of transmission line fault transient noise statistics were studied. Simulation results show that . When the line fails, current, voltage, significantly different noise characteristics and noise characteristics are directly related with the fault type . In terms of distance protection , due to phase fault , the fault phase current and voltage from phase noise characteristics of the fault type of impact, therefore, the relevant characteristics of the noise power can be attributed to the single-phase fault and two basic types of three-phase fault . Given the different type of fault conditions, significant difference between the noise , so filtering algorithm for microprocessor-based protection and protection setting should be selected according to different fault types , respectively ,[link widoczny dla zalogowanych], to optimize protection performance.


Post został pochwalony 0 razy
Powrót do góry
Zobacz profil autora
Wyświetl posty z ostatnich:   
Napisz nowy temat   Odpowiedz do tematu    Forum Forum MESA !! Strona Główna -> Wyniki Wszystkie czasy w strefie EET (Europa)
Strona 1 z 1
   
 
Opcje 
Zezwolenia Opcje
Kto jest na Forum Możesz pisać nowe tematy
Możesz odpowiadać w tematach
Nie możesz zmieniać swoich postów
Nie możesz usuwać swoich postów
Nie możesz głosować w ankietach
Kto jest na Forum
 
Jumpbox
Kto jest na Forum
Skocz do:  


fora.pl - załóż własne forum dyskusyjne za darmo
Theme FrayCan created by spleen & Download
Powered by phpBB © 2001, 2005 phpBB Group
Regulamin